Gallium (Ga) and indium (In) are essential for optoelectronic and photovoltaic (PV) applications. However, primary sources are limited, while recoverable metals exist in industrial effluents and end-of-life modules. In this study, a solar-assisted bioelectrochemical system (BES) is evaluated, in which a photovoltaic (PV) module directly biases a bioanode-based, two-chamber reactor. This setup facilitated the anodic half reaction and supplementary driving force under mild aqueous conditions. During seven-day batch operations on a real Ga-bearing semiconductor effluent and a synthetic In solution, a PV-assisted BES at ~1.25 V removed 88% of Ga, reducing concentrations from 1016 ± 4 to 127 ± 1 mg/L. In contrast, a self-biased microbial fuel cell (MFC) and an open-circuit (OC) control removed only 17% and 15% of Ga, respectively. Initial In concentrations (1005 ± 1 mg/L) declined by 31%, 29%, and 26% in MFC, PV-assisted BES, and OC modes, respectively. Scanning electron microscopy (SEM)-energy-dispersive X-ray (EDX) analysis revealed In-rich precipitates (~58 wt% In). The contrasting responses of Ga and In derive from their reduction potentials and interfacial chemistry: Ga3+ reduction requires stronger polarization, whereas In3+ can deposit under milder bias. Accordingly, PV assistance is essential for Ga removal but less critical for In stabilization. This BES can reduce energy and chemical inputs compared with conventional pyro- and hydrometallurgical routes and highlight these divergent recovery behaviors as a foundation for sustainable valorization of metal-bearing effluents.

INTRODUCTION

Gallium (Ga) and indium (In), key group-13 metals, are critical components in transparent conductors, including indium–tin oxide (ITO), in high-efficiency light-emitting and power devices based on gallium nitride (GaN) and gallium arsenide (GaAs), and in thin-film photovoltaics (PVs) [1]. The major issue with their consumption is that their reserves are scarce and regionally concentrated, but demand continues to expand as electronics and clean energy continue to emerge [2]. Effluents and wastewater from semiconductor and display manufacturing are valuable secondary resources, and their laboratory analogs can effectively model such real systems for mechanistic evaluation [3]. To mitigate supply risks and ensure environmental compliance within a circular economy framework, it is essential to form efficient recovery from these dilute and complex aqueous matrices [2].
There are multiple approaches to recovering metal from water. These techniques include chemical precipitation, cementation, solvent extraction (SX), ion exchange, adsorption, electrochemical processes, such as electrowinning, electrocoagulation, and electrodialysis, as well as membrane separations, including nanofiltration (NF), reverse osmosis (RO), and liquid membranes [3–6]. However, many approaches demand intensive reagents or energy input, produce secondary wastes, or lose selectivity in real wastewater. Ga’s amphoteric nature further complicates separation, as Ga(OH)3 precipitates between pH 4 and 7 but redissolves to cationic or gallate species outside this range, reducing the effectiveness of precipitation and adsorption [7]. Such complexity often requires multiple purification steps [8] and strong chemical conditions [9]. High-temperature and strong-acid processes achieve near-quantitative yields, but they are energy-intensive and corrosive. Therefore, there is a critical need for alternative strategies under milder conditions that minimize chemical dosing and remain effective at low metal concentrations. In semiconductor and display manufacturing effluents, gallium and indium are typically detected at concentrations ranging from several tens to a few thousand milligrams per liter, mainly present as Ga3+/Ga (OH)4- and In3+/In (OH)2+ species depending on pH [2,3].
Recently, bioelectrochemical systems (BESs), particularly microbial fuel cells (MFCs), have emerged as alternatives of conventional processes. The systems integrate microbial oxidation at the anode with cathodic metal recovery through reduction, precipitation, or adsorption, minimizing reagent use [10,11]. Many studies demonstrate metal recovery using the intrinsic potential of MFCs [12,13], while others enhance performance by applying external bias from grid power. There are two critical limitations still remained. First, self-biased MFCs typically suffer from low cell voltage and sluggish kinetics [14,15]. Second, externally biased cells without an anodic electron input often depend on oxygen evolution (OER), leading to corrosion, passivation, and instability [16]. These limitations underscore the need for hybridization—specifically, a BES that utilizes a bioanode to oxidize organic waste and supply electrons for stable anodic reactions, coupled with a renewable bias to overcome kinetic bottlenecks, as proposed in this study.
This study demonstrated a solar-assisted BES for recovering the group-13 metals, In and Ga. The renewable energy bias compensates for the limited driving force of self-biases MFCs, thereby enhancing Ga(III) removal through increased cathodic overpotential and local proton consumption, while enabling In(III) recovery primarily through electrode deposition under moderate polarization that avoids redissolution. The bioanode oxidizes organic substrates to supply electrons and stabilize the anodic half reaction, thereby suppressing OER-driven degradation. This observation was examined by quantifying solution phase concentrations and conducting post-run scanning electron microscopy (SEM)-energy-dispersive X-ray (EDX) on cathodes. The analyses used a Ga-bearing semiconductor effluent and a In solution to distinguish metal-specific responses to bias.

MATERIALS AND METHODS

Chemicals and synthetic solutions

A synthetic In solution (1000 mgL–1) was prepared by dissolving In chloride (InCl3·4H2O, Samchun Chemicals, Korea) in deionized water, yielding a pH of 2.3 without adjustment. Ga solution was obtained from semiconductor etching wastewater [17], originating from GaN wafer wet etching (pH = 0.3). The raw wastewater, with a strongly acidic pH of 0.3, was diluted to ~1000 mg L–1 Ga to serve as the catholyte. After dilution, the pH of the working solution was adjusted back to ~0.3 using HCl to reproduce the acidity of the original wastewater. The indium concentration (~1000 mg L–1) corresponds to the upper range reported for industrial effluents and was previously validated in an MFC-based indium recovery study [18]. Apart from dilution to experimental working volumes, no further modifications were applied.

Reactor configuration

Metal recovery experiments were performed in dual-chamber BESs (250 mL per chamber) separated by a proton-exchange membrane (Nafion 212, Chemours). Side arms of the chamber were sealed with butyl rubber stoppers and aluminum crimps (three on the anode chamber and two on the cathode chamber). The anode comprised commercial carbon felt (Fuel Cell Store, USA; 4 × 5 cm, 0.6 mm thick) fully submerged in the anolyte. The cathode consisted of ITO-coated glass (1500 Å ITO layer on 0.5 mm glass, IMAT) cut to 2 × 4 cm and 2 × 6 cm pieces, with a constant immersed area of 2 × 3 cm. Electrical leads were attached to the ITO with silver paste and sealed with epoxy to prevent leakage and corrosion.

Operating modes

The bioanode was inoculated with a mixed microbial community obtained from anaerobic activated sludge collected at the Korea Environmental Corporation (Gwangju, Republic of Korea). Three operational modes were evaluated in identical reactors. In the open-circuit (OC) control, electrodes were submerged without any external connection. In the self-biased MFC mode, the anode and cathode were linked through a 1kΩ resistor, with microbial metabolism providing the acthodic reactions. In the soalr-assisted BES mode, a 60 × 80 mm PV panel was connected in series with the cell to provide ~1.25 V bias. The bioanode oxidized glucose to supply electrons, while the PV input enhanced cathodic reactions for metal recovery. Polarity remained constant across all tests, with the bioanode functioning as the electron source and the ITO electrode as the electron sink. Each batch cycle lasted seven days, after which the anolyte and the metal-bearing catholyte (synthetic In or Ga solution) were replenished for the next cycle. All experiments were conducted at room temperature (25 ± 5°C). All experiments were conducted in triplicate (n = 3), and the reported concentrations represent mean ± standard deviation.

Sampling and analysis

Catholyte samples (5 mL) were collected at days 0 and 7 from unstirred reactors, decanted from the supernatant, and filtered through 0.2 μm syringe filters. To ensure consistent quantification, no mechanical stirring was applied before sampling so that electrode-adjacent aggregates and settled particulates were not re-suspended. The filtered supernatant therefore represents only the dissolved and sub-0.2 μm fraction, excluding electrode-bound layers, wall or membrane deposits, and gravity-settled solids from the ICP readout. Filtrates were stored at 4°C until analysis. In and Ga concentrations were quantified by inductively coupled plasma-optical emission spectrometer (ICP-OES; iCAP 7400 Duo MFC, Thermo Fisher Scientific, USA), using argon as the plasma, auxiliary, and nebulizer gases. Removal efficiency (%) was computed as C0-CtC0×100, where C0 and Ct represent the initial and seven-day concentrations, respectively.

Cathode characterization

After each run, ITO cathodes were gently rinsed with deionized water, air-dried, and analyzed by SEM (JEOL JSM-IT300) equipped with EDS (Oxford Aztec Energy X-Max, 50 mm2). Pristine ITO electrodes were examined as controls under identical conditions. In addition, air-dried precipitates collected from the catholyte were analyzed by XRD (Rigaku SmartLab 9 kW, Cu Kα source).

Thermodynamic/kinetic visualizations

Simplified Pourbaix diagrams and Butler–Volmer (BV) competition plots were generated in Python using standard electrochemical reactions. The thermodynamic data and standard potentials were adapted from previous electrochemical and thermodynamic analyses of Ga and In systems [19,20]. The diagrams, constructed from standard potentials and mass-action relations, included the H⁺/H2, O2/H2O, Ga3+/Ga, In3+/In, and representative oxide/hydroxide boundaries, with activities estimated from the initial solutions (SI). BV curves compare Ga3+ or In3+ reduction with the hydrogen evolution reaction (HER) on ITO, using representative parameters (exchange current density, charge-transfer coefficient, and a diffusion-limited current; SI). These visualizations provide qualitative guidance rather than quantitative fitting.

RESULTS AND DISCUSSION

System validation and operating modes

A bioanode-based BES was assembled to ensure consistent anodic electron delivery and minimize OER under external bias. The anode community was pre-enriched over two months through eight consecutive seven-day transfers in ferricyanide medium, yielding a reproducible electroactive consortium [10]. After enrichment, the cell generated a self-biased baseline of ~150 ± 30 mV across a 1 kΩ resistor, consistent with small glucose-fed MFCs and indicative of sustained anodic electron delivery [10,18]. The voltage output was checked prior to the main experiments and confirmed to be stable within this range, consistent with small glucose-fed MFCs and indicative of sustained anodic electron delivery. This baseline voltage (~150 mV across a 1 kΩ resistor) corresponds to a power density of approximately 30–40 mW m–2 based on the projected electrode area (2 × 3 cm), which falls within the typical range reported for laboratory-scale MFCs. A compact PV module (~1.25 V) was directly coupled across the two-chamber cell to establish the solar-assisted mode, while the bioanode remained the anodic electron source. Fig. 1 presents the system configuration and the three operating modes: OC, self-biased MFC, and solar-assisted BES.

Reduction-driven removal of Ga and In from the supernatant

In all batches, “removal” denotes the reduction of dissolved and sub-0.2 μm metal in the quiescent supernatant after syringe filtration. Before sampling, mechanical stirring was avoided to allow solids and electrode-adjacent aggregates to settle. The filtered supernatant represents only the bulk solution fraction, excluding electrode-bound layers, wall or membrane deposits, and gravity-settled particulates from the ICP readout.
For the Ga-bearing effluent, a marked decline in supernatant concentration occurred under solar-assisted operation, whereas self-biased MFC and OC showed similarly modest changes (Fig. 2). The behavior arises from the differing reduction requirements of the two metals in water, where EGa3+/Gao demands a more negative potential than In, so the low cell voltages of self-biased MFCs fail to provide sufficient cathodic overpotential for extensive Ga(III) removal [18,21].
Half-reactions:
Ga3++3e-→Ga(s) Eo ≈ -0.53 V vs SHE
In3++3e-→In(s) Eo ≈ -0.34 V vs SHE
In contrast, a direct PV bias of ~1.25 V provided sufficient potential to drive broad Ga(III) reduction and deplete it from the detectable supernatant pool. After seven days, Ga concentrations decreased from 1016.0 ± 3.7 mg L–1 to 842.4 ± 1.1 mg L–1 in the MFC (17.1% removal), 865.5 ± 4.6 mg L–1 in the OC control (14.8% removal), and 126.7 ± 0.7 mg L–1 in the solar-assisted BES (87.5% removal) (Fig. 2).
For the In system, the supernatant concentration declined modestly across all modes with minimal variation (Fig. 3). From an initial 1005.3 ± 1.3 mg L–1, the concentrations after seven days were 699.2 ± 1.5 mg L–1 in the MFC (30.5% removal), 718.4 ± 2.3 mg L–1 in the BES (28.5% removal), and 740.2 ± 2.3 mg L–1 in the control (26.4% removal). These reductions suggest that In(III) undergoes partial removal from the dissolved or sub-micron fraction even under mild self-bias. The apparent indium removal observed under open-circuit conditions likely originated from spontaneous adsorption or precipitation processes rather than electrochemical reduction. Minor adsorption of In3+ species onto ITO, the membrane, or vessel walls, and incipient precipitation of In(OH)3 or colloidal species under acidic conditions (pH ≈ 2.3) could reduce the measured concentration in the filtered supernatant. The modest decline also results from the limited 2 × 3 cm electrode area, which restricts interfacial contact and mass transfer relative to porous carbon cathodes that enable near-quantitative removal [18]. ITO was intentionally selected to allow area-normalized interpretation and subsequent surface characterization; however, in the solution phase metrics, this constraint yields partial rather than complete reduction-driven loss from the filtrate.

Surface characterization and phase evolution

Ga-loaded ITO samples could not be reliably imaged under high-vacuum SEM/EDX conditions. Therefore, Ga surface micrographs and EDX spectra are not presented, and this limitation is acknowledged. This limitation might arise from strong beam-induced instability and detachment of loosely bound Ga-rich aggregates under high-vacuum conditions, preventing acquisition of reproducible micrographs; therefore, interpretation of Ga reduction relies on solution-phase depletion and XRD-verified Ga(0) formation rather than surface imaging.
To identify phases produced under PV-assisted operation, catholyte precipitates were collected, rinsed, dried, and analyzed by powder X-ray diffraction (Fig. 4). The diffractogram exhibits reflections of orthorhombic metallic Ga (α-Ga, C-centered) that are absent from blank materials. XRD analysis of the recovered solids showed diffraction peaks corresponding to α-Ga (orthorhombic Ga(0)), suggesting that Ga(III) was reduced to metallic Ga as a solid phase rather than forming a coherent film on ITO. The assignment aligns with the indexing results, with reference α-Ga peak positions (Cu Kα₁) showing a uniform −0.145° zero-shi, from peak matching.
In generated distinct surface features on ITO. Compared with pristine ITO (Fig. 5a), post-run cathodes exhibited extensive granular to faceted deposits (Fig. 5b–c). The self-biased MFC formed a dense, continuous layer, whereas solar-assisted operation produced thinner, discontinuous coverage, reflecting rapid deposition followed by partial detachment under stronger polarization over the seven-day batch. EDX mapping revealed widespread In signals, with spectra indicating ~58 wt% In and ~32 wt% oxygen, along with Sn and Si contributions from the ITO substrate (Fig. 6, Table 1). Despite In being intrinsic to ITO, the pronounced morphological changes relative to pristine ITO and the EDX-detected In enrichment indicate additional In deposition during operation. The crack-like features observed in the post-MFC sample (Fig. 5c) are attributed to localized mechanical stresses and drying-induced fragmentation within relatively thick In-rich deposits, rather than to an inherent instability unique to the MFC mode; regions with thinner coverage displayed smooth surfaces, indicating that the cracks are localized rather than mode-specific. The substantial reduction in the Si signal is attributed not to Si depletion but to masking of the glass substrate by the newly formed In-rich overlayer, which attenuates the Si contribution within the shallow probing depth of EDX.
The faceted and rectangular morphology of In reflects a two-step deposition process previously described for oxide supports under mild bias [18]. First, cathodic electron transfer coupled with local proton consumption drives nucleation of In-rich hydroxide or oxide on the ITO surface. Second, dehydration and lattice ordering during drying or beam exposure transform these precursors into faceted crystallites. The crystalline framework of ITO further directs oriented growth, giving rise to square or rectangular platelets. The thicker and more continuous layer under self-biased operation indicates that mild polarization stabilizes the deposits, whereas the stronger bias in the solar-assisted mode promotes concurrent formation and loss, yielding a thinner layer at sampling. The SEM-EDX evidence confirms In capture as surface-bound solids on ITO, while the absence of Ga surface data reflects imaging limitations under high vacuum, rather than the absence of solution-phase Ga removal (Section 3.2).

Mechanistic interpretation and bias-dependent pathways

The solution-phase trends (Section 3.2) together with the surface evidence indicate bias-dependent and element-specific pathways. Bulk pH measurements (Fig. S1) showed that the indium system experienced a substantial increase in pH from 2.3 to 4.0, a range that thermodynamically favors hydrolysis and oxyhydroxide formation. In contrast, the gallium system remained strongly acidic (pH < 1.5), indicating that Ga speciation was largely unchanged and that its removal required electrochemical reduction rather than pH-driven precipitation. For Ga, notable depletion from the filtrate occurred only under PV assistance. Powder XRD of the catholyte precipitate confirmed the presence of α-Ga [Ga(0)] (Fig. 4), consistent with electrochemical reduction of Ga(III). Fig. 7a presents a Pourbaix diagram incorporating the water-stability lines (H+/H2 and O2/H2O, dashed), the pH-independent Ga3+/Ga line, and an approximate Ga2O3/Ga boundary. The shaded band denotes the bulk acidity of the Ga effluent (pH_bulk ≈ 0.3). At this acidity, access to the Ga(0) stability field requires potentials more negative than E°(Ga3+/Ga) = −0.53 V vs SHE. Such bias surpasses the typical output of self-biased MFC voltages, yet ≈1.25 V from a PV bias supplies the necessary overpotential and electron flux [22]. In quiescent cells, cathodic hydrogen evolution reaction (HER) and oxygen reduction reaction (ORR) deplete local protons and oxygen at the ITO interface, generating a highly reducing micro-environment. Consequently, Ga deposits as thin, weakly adherent interfacial films and loose aggregates that readily detach, accounting for significant supernatant loss. Ga-rich material proved unstable under high-vacuum SEM, indicating beam-induced mobility or outgassing.
For In, the bulk pH (≈2.3) and relatively less-negative In3+/In potential (E° ≈ −0.34 V vs SHE) allow partial reduction and facilitate localized In(OH)3 precipitation under cathodically elevated interfacial pH [19]. The Pourbaix map (Fig. 7b) positions the In(OH)3 precipitation boundary at pH ≈ 3–4. This observation indicates that even mild polarization suffices to nucleate deposits on the ITO surface, yielding the granular and faceted deposits observed by SEM/EDX. Although the standard potential of In3+/In (−0.34 V) is more positive than that of Ga3+/Ga (−0.53 V), the Pourbaix analysis indicates that the effective reduction behavior under the respective pH and interfacial conditions differs significantly, leading to stronger bias dependence for Ga and more limited overall conversion for In. Higher PV bias accelerates formation and partial redissolution of detachment, explaining the comparatively thinner surface coverage and the moderate solution-phase depletion over a seven-day batch using a planar, low-area ITO cathode (2 × 3 cm).
Order-of-magnitude BV estimates (Supplementary Information, Fig. S2–S3) support these interpretations. Under the PV-assisted window at pH ≈ 0.3, predicted Ga3+/Ga currents exceed HER by orders of magnitude, whereas In reduction at pH ≈ 2.3 remains kinetically accessible under milder polarization, consistent with moderate supernatant loss yet substantial surface deposition.
The bioanode is pivotal in both cases. In externally biased systems without an anodic electron donor, OER predominates, causing energy penalties and electrode deterioration. The bioanode, by continuously oxidizing organics, stabilizes the anode and channels the applied solar bias toward cathodic reactions that drive supernatant loss and solid-phase capture.

Practical implications and outlook

Our results indicate that renewable-assisted BES achieve significant Ga removal from the 0.2 μm-filtered supernatant only under the applied bias. In contrast, In capture proceeds even under mild polarization, with metal-specific outcomes determined by the polarization strength and interfacial area. In quiescent and unstirred batches, bias facilitates conversion of dissolved or sub-0.2 μm pool. The fate of these products (whether retained on the electrode or lost via aggregation and settling) depends on the local potential–pH microenvironment and available surface area, consistent with Pourbaix guidance (Fig. 7).
Although PV provides sufficient potential to reduce each metal ions, maintaining anodic stability is critical for the stable and sustainable operation. Replacing the bioanode with an abiotic anode under bias led to rapid deterioration from OER-driven corrosion and passivation (data not shown). In contrast, the bioanode sustained electrons from organics, stabilizing the anodic half-reaction and enabling the solar bias to drive towards cathodic conversions.
Ga-rich effluents exhibit enhanced removal under solar-assisted bias, which surpasses the Ga3+/Ga threshold (Fig. 7a) and promotes proton consumption near the cathode. Maintaining quiescent conditions facilitates the transfer of transformed species from the filtrate through attachment or settling. In-bearing streams undergo partial reduction under mild polarization (self-biased or low-bias), with increased cathode surface area (porous carbon) stabilizing deposition and limiting redissolution. Planar ITO remains valuable for area-normalized interpretation and surface diagnostics; however, it limits absolute removal in batch systems. The XRD-verified Ga(0) (Fig. 4) and SEM/EDX-confirmed In deposits (Fig. 5 and 6) serve as complementary reference points for optimizing bias windows.
The next steps for scale-up and optimization are outlined below:
1) Planar ITOs are replaced with porous, high-area cathodes to increase areal productivity, while retaining a subset of analytical electrodes for diagnostic.
2) Flow-through or flow-by configurations are implemented to control boundary layers and decouple nucleation from detachment.
3) PV is integrated with simple DC conditioning (current limiting or MPPT) to maintain metal-specific polarization within the ranges indicated in Fig. 7.
For process engineering, future experiments should record current and voltage to determine coulombic efficiency and energy intensity (kWh kg–1 metal) and complete the mass balance by quantifying electrode-bound, settled/filtered, and residual fractions through post-run stripping and ICP analysis. When an abiotic carbon-felt anode was tested under identical bias (~1.25 V), severe corrosion and mechanical fracture occurred due to oxygen evolution, confirming that stable operation is achievable only with a bioanode (Fig. S4). The PV-assisted bias (~1.25 V) corresponds to an estimated energy intensity below 0.05 kWh kg–1 metal, substantially lower than conventional electrowinning processes that typically require 3–5 V and > 1kW h kg–1 metal [3]. Although detailed current–voltage logging was not performed in this proof-of-concept stage, these values illustrate the markedly reduced external energy requirement of the solar-assisted BES configuration and will be quantitatively analyzed in future scale-up studies.

CONCLUSION

Direct PV coupling (~1.25 V) to a bioanode-driven BES facilitated the recovery of group-13 metals. For Ga-containing effluent, the PV-assisted operation removed 87.5% of Ga, compared with 17.1% in the self-biased MFC and 14.8% under OC conditions, with XRD confirming metallic Ga(0) formation. In solution concentrations declined by 28–30% in all modes, with SEM/EDX confirming ITO-bound deposits containing ~58 wt% In. Replacing the bioanode with an abiotic anode under bias caused rapid anode deterioration, highlighting the critical role of an anodic electron source in preventing OER-driven damage. These findings confirm the efficacy of renewable-assisted BES for Ga and In recovery, emphasizing the need for bias tuning (stronger for Ga, milder for In) and higher-surface-area cathodes for practical implementation.

Notes

ACKNOWLEDGMENTS

This study was financially supported by Chonnam National University (Grant number: 2022-2547). This study was also supported by Research Development Project of Gwangju Green Environment Center (No. 24-04-10-12-12).

DECLARATION OF GENERATIVE AI AND AI-ASSISTED TECHNOLOGIES IN THE WRITING PROCESS

During manuscript preparation, the authors employed generative AI (ChatGPT-5) solely to improve readability and language quality. No AI or AI-assisted technologies were used for scientific content, data analysis, or conceptualization of this study. All AI outputs were carefully reviewed and edited by the authors to ensure accuracy, integrity, and impartiality. In accordance with the journal’s guidelines and Elsevier’s AI policy for authors, AI tools were neither credited as authors nor cited as contributors to the manuscript. The authors retain full responsibility and accountability for the content of this work.

Fig. 1.
Dual-chamber solar-assisted BES: the bioanode, membrane, and ITO cathode.
jecst-2025-01053f1.jpg
Fig. 2.
Ga concentrations after seven days under OC, MFC, and BES conditions.
jecst-2025-01053f2.jpg
Fig. 3.
In concentrations after seven days under OC, MFC, and BES conditions.
jecst-2025-01053f3.jpg
Fig. 4.
XRD pattern of the sample (black labels) compared with the reference diffraction peaks of metallic β-Ga (red labels, COD 9008562, Cu Kα). Vertical dashed lines indicate all detected peaks.
jecst-2025-01053f4.jpg
Fig. 5.
SEM micrographs of ITO: (a) pristine, (b) post-BES, and (c) post-MFC operations.
jecst-2025-01053f5.jpg
Fig. 6.
EDX mapping and spectrum of In precipitates with elemental composition shown in the inset.
jecst-2025-01053f6.jpg
Fig. 7.
Simplified Pourbaix diagrams at 25°C, qualitatively showing activities approximated for: (a) Ga, and (b) In.
jecst-2025-01053f7.jpg
Table 1.
Quantitative EDX composition of the ITO cathode before (pristine) and after indium recovery in the solarassisted BES.

Before operation (pristine ITO)
After operation (post-run ITO)
Element Wt% Atomic % Wt% Atomic %
C 0.0 ± 0.0 0.0 4.1 ± 0.2 11.4
O 22.9 ± 0.3 47.1 32.3 ± 0.4 66.9
Al 0.6 ± 0.1 0.7 0.6 ± 0.1 0.7
Si 25.5 ± 0.2 29.9 2.2 ± 0.1 2.6
Cl 4.6 ± 0.1 3.7 0.9 ± 0.0 0.8
Ca 0.0 ± 0.0 0.0 0.6 ± 0.1 0.5
In 37.4 ± 0.4 10.7 58.4 ± 0.4 16.9
Sn 3.8 ± 0.4 1.1 0.9 ± 0.3 0.3
Na 3.2 ± 0.1 4.6 0.0 ± 0.0 0.0
Mg 1.1 ± 0.1 1.4 0.0 ± 0.0 0.0
K 1.0 ± 0.2 0.9 0.0 ± 0.0 0.0
Total: 100 100 100 100

REFERENCES

[1] J. Kluczka, Resources, 2024, 13(3), 35.
crossref
[2] K. Zheng, M. F. Benedetti and E. D. van Hullebusch, J. Environ. Manage., 2023, 347, 119043.
crossref
[3] D. Teng, J. Wu, Q. Ma, W. Wang, G. Zhou, G. Fan, Y. Cao and P. Li, ACS Omega, 2025, 10(1), 76–92.
crossref pdf
[4] T. Zhang, T. Jiang and Z. Liu, Miner. Eng., 2019, 136, 155–160.
crossref
[5] S. Gu, T. Tominaka, G. Dodbiba and T. Fujita, J. Chem. Eng. Jpn., 2018, 51(8), 675–682.
crossref
[6] Q. Song, L. Zhang and Z. Xu, J. Hazard. Mater., 2020, 381, 120973.
crossref
[7] Y. Xiong, X. Cui, D. Wang, Y. Wang, Z. Lou, W. Shan and Y. Fan, Mater. Sci. Eng. C, 2019, 99, 1115–1122.
crossref
[8] S. Virolainen, D. Ibana and E. Paatero, Hydrometallurgy, 2011, 107, 56–61.
crossref
[9] H.-I. Hsiang, C.-C. Chen and C.-Y. Chiang, Metals, 2023, 13(5), 893.
crossref
[10] C. Kim, C. R. Lee, Y. E. Song, J. Heo, S. M. Choi, D.-H. Lim, J. Cho, C. Park, M. Jang and J. R. Kim, Chem. Eng. J., 2017, 328, 703–707.
crossref
[11] Y. V. Nancharaiah, S. V. Mohan and P. Lens, Bioresour. Technol., 2015, 195, 102–114.
crossref
[12] G. Wang, L. Huang and Y. Zhang, Biotechnol. Lett., 2008, 30, 1959–1966.
crossref pdf
[13] A. T. Heijne, F. Liu, R.v.d. Weijden, J. Weijma, C. J. N. Buisman and H. V. M. Hamelers, Environ. Sci. Technol., 2010, 44, 4376–4381.
crossref
[14] H. Beyenal, I. S. Chang, S. V. Mohan and D. Pant, Bioresour. Technol., 2021, 124687.

[15] R. Selvasembian, J. Mal, R. Rani, R. Sinha, I. Joshua, A. Santhiagu and N. Pradhan, Bioresour. Technol., 2022, 346, 126462.
crossref
[16] E. Kim, J. Lee, M. Kim, S. Cha, N. C. Maile, H. Kim and J. R. Kim, Chem. Eng. J., 2025, 519, 165058.
crossref
[17] H. Ryu, H.-J. Choi, M. Kulkarni, H. Rho, H. Lim, S.-W. Ryu, J.-S. Ha and S. H. Lee, Appl. Surf. Sci., 2024, 661, 160040.
crossref
[18] C. Kim, C. R. Lee, J. Heo, S. M. Choi, D.-H. Lim, J. Cho, S. Chung and J. R. Kim, Bioresour. Technol., 2018, 258, 203–207.
crossref
[19] Y.-H. Chung and C.-W. Lee, J. Electrochem. Sci. Technol., 2012, 3, 1–13.
crossref pdf
[20] B. Swain, C. Mishra, K. J. Lee, H. S. Hong, K.-S. Park and C. G. Lee, Int. J. Appl. Ceram. Technol., 2016, 13, 280–288.
crossref
[21] M. Saeed and O. I. G. Peña, Nanomaterials, 2021, 11(5), 1222.
crossref
[22] J. Kang, T. Mitsuhashi, K. Kuroda and M. Okido, J. Appl. Electrochem., 2019, 49, 871–881.
crossref pdf
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 1 Crossref
  •   Scopus
  • 2,339 View
  • 109 Download
Related articles in J. Electrochem. Sci. Technol


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
E-mail: journal@kecs.or.kr    Tel: +82-2-568-9392               

Copyright © 2026 by The Korean Electrochemical Society.

Developed in M2PI

Close layer
prev next