J. Electrochem. Sci. Technol Search

CLOSE


J. Electrochem. Sci. Technol > Volume 12(3); 2021 > Article
Park, Lee, and Hwang: Electrochemical Capacitance of Activated Carbons Regenerated using Thermal and Chemical Activation

Abstract

Spent activated carbons (SACs) collected from a water treatment plant were regenerated and then adopted as electrochemical material in capacitors. The SACs used in this study were regenerated via two steps, namely thermal and chemical activation. However, during the activation process, the adsorbates were converted into ashes, which caused pore blockage and decreased specific surface area. The regenerated SACs were washed with acid solutions with different levels of acidity (strong: HCl, mild: H3PO4, and weak: H2O2) to remove the ashes. The regenerated SACs washed with HCl exhibited the highest specific surface area, although their capacitance was not the highest. Conversely, the specific surface area of regenerated SACs washed using H3PO4 was slightly lower than that of HCl, but exhibited higher capacitance and electrochemical stability. Although the strong acid removed the generated ashes in the pores efficiently, it could adversely affect their structural stability, which would lead to lower capacitance.

1. Introduction

Activated carbons (ACs) have been used in pollution remediation in both liquid and gas phase effluent from industries [1]. The pollutants are usually adsorbed onto AC surfaces before being released into the atmosphere or water, which prevents environmental pollution [13]. ACs are usually disposed in landfills or thermally regenerated when they lose their adsorption capacity [4,5]. For example, according to previous reports, over 70% of spent ACs (SACs) generated by the industrial complex (Yeo-su) in South Korea are disposed in landfill sites [6]. While fresh ACs are used in pollutant remediation, SACs could lead to secondary environmental pollution, such as soil poisoning [3,6].
The potential reuse of SACs following regeneration has attracted the attention of environmental researchers [6,7]. To date, SAC regeneration has been studied extensively. SACs could be regenerated using various approaches, such as thermal and chemical treatments, and chemical activation [8]. Among the methods, thermal regeneration has been applied extensively due to its relative simplicity and low associated costs [9,10].
SACs can be classified into two categories based on whether they remove pollutants in the 1) gas or 2) liquid phase. ACs have been used widely to remove gas pollutants such as volatile organic compounds (VOCs). The VOCs adsorbed on the ACs are removed or decomposed efficiently by thermal treatment, and then ACs regenerated [6]. However, ACs used in removal of pollutants from water require relatively high energy levels due to the associated high latent heat of vaporization, in addition to the relatively complex regeneration process required [11]. Specifically, ACs adsorb various metallic ions in water, and then the metal ions are converted into ash during thermal regeneration (as illustrated in Fig. 1) [12]. The thermal regeneration process evaporates the moisture; however, the adsorbed metal ions cannot be eliminated and they remain in the pores [4,13,14], which decreases their surface area. Consequently, an additional process is required to remove the ash prior to the use of regenerated ACs.
A previous report has already highlighted the limitations of thermal regeneration with regard to SACs. Han et al. regenerated ACs using the three methods, including heat treatment, ultrasonication, and solvent extraction [13]. Both ultrasonication and solvent extraction methods exhibited regeneration rates superior to that of thermal regeneration because coke deposits on micropores under thermal regeneration were eliminated. In addition, Sabio et al. recommended thermal regeneration using gasifying agents (carbon dioxide and air) to facilitate complete regeneration [4]. The SACs thermally regenerated using the gasifying agents had increased micropores, performing the initial capacity. Bagreev et al. also regenerated SACs by heating in the atmosphere [14]. The thermal treatment using the air removed residues in the pores, and the results exhibited 100% pore regeneration. As aforementioned, the previous reports also extensively explored pore blockage caused by ashes and coke through thermal treatment, because the removal of ash from pores is a key aspect of SAC regeneration.
In the present study, the SACs were thermally regenerated, and then chemically activated, according to the schematic presented in Fig. 1. Chemical activation often enhances AC surface area, after which they could be used in various applications. The regenerated ACs using the only thermal treatment was limited to the application because of the generated ashes and decreased surface areas. Therefore, in previous studies, regenerated ACs have been mostly reused for pollutant removal. However, the ACs regenerated in the present study using both thermal and chemical activation methods had relatively high surface areas, so that they could be applied in electrochemical materials such as capacitors. In addition, the ashes generated on the regenerated ACs following both treatments were removed efficiently using various acid treatments. The relationship between ash removal and surface area was investigated, in addition to the pores created by ash removal. Furthermore, the electrochemical properties of the ACs were also investigated. The electrochemical properties of the ACs produced using both the thermal and chemical activations were enhanced, and the properties were also superior to those of the ACs regenerated using the previous method, such as thermal or chemical treatment. The regeneration method that is introduced in the present study could be a new guideline for SAC regeneration and reuse.

2. Materials and Methods

2.1. Regeneration of spent ACs (SACs)

SACs were collected from a water purification plant in Gyeonggi-do Province, South Korea. The collected SACs were dried in an oven at 100°C over-night prior to use. The dried SACs were thermally regenerated at 500°C for 10 h. The thermally regenerated SACs are hereafter referred to as H-SACs. In addition, the H-SACs were chemically regenerated using the 95% potassium hydroxide (KOH) (Samchun Chem. Co., Korea). First, the H-SACs were mixed with KOH at a weight ratio of 1:2 (H-ACs: KOH = 1:2), and then the mixture was placed in a vertical furnace. The sample mixtures in the furnaces were heated gradually until 750°C, with heat ramped up at a rate of 5°C/min. The temperature was maintained at 750°C for 1 h. After the KOH treatment process, the temperature was increased again up to 850°C, where it was maintained for 3 h [15].
The chemically activated H-SACs are hereafter referred to as C-SACs. The C-SACs were treated with three acid solutions to remove the ashes produced. Hydrogen chloride (35%) (HCl, Samchun Chem. Co.), 85.0% phosphoric acid (H3PO4, Sigma Aldrich), and 34.5% hydrogen peroxide (H2O2, Samchun Chem. Co.) were used for the acid treatments. After chemical activation, the samples were washed using tap water and then treated with 0.5 M of each acid solution. The samples treated with the acids are hereafter referred to as C-SAC-treated acids (for example, C-SAC-HCl was treated with HCl solution).

2.2. Characterization of prepared ACs

The surface areas and pore distributions of prepared samples (SAC, H-SAC, C-SAC-HCl, C-SAC-H3PO4, and C-SAC-H2O2) were analyzed using the Brunauer–Emmett–Teller and Barret–Joyner–Halenda (BJH) method based on the nitrogen adsorption obtained at 77 K using a TriStar II (Micromeritics, USA) static volumetric analyser. Elemental analysis (EA) was conducted using an elemental analyser (FlashEA 1112 and FlashEA 2000, Thermo Fisher Scientific, Waltham, MA, USA) to determine the elemental concentrations (carbon, hydrogen, oxygen, nitrogen, and sulphur). For the proximate analysis, the samples were placed into a DF-4S furnace (Daeheung Science, Incheon, Korea). The samples were heated at 950°C for 7 min, and then the temperature was decreased to 750°C for 10 h. The ash, volatile matter, and fixed-carbon contents within the ACs were presented as percentages by weight. The content of carbon functional groups in the samples was confirmed via X-ray photoelectron spectroscopy (XPS, PHI-5000 VersaProbe (Ulvac-PHI)).

2.3. Electrochemical capacitance measurement

The capacitances of the samples were measured using the cyclic voltammetry (CV) method using a three-electrode system consisting of counter (platinum wire), reference (Ag/AgCl electrode), and working electrodes, linked to an electrochemical workstation (AUT302M, FRA2, Metrohm Autolab, Utrecht, The Netherlands). First, 10 mg of AC powder was mixed with 0.1 mL of 5 wt% Nafion solution and 0.3 mL of 99.5% tert-Butanol (C4H10O, Daejung Chem. Co.), with brief sonication. Subsequently, 6.0 μL of the prepared slurry was dropped onto a glassy carbon electrode, which acted as a working electrode [16]. Testing was conducted at different scan rates (10–100 mV/s) using a 0.5M H2SO4 solution as an electrolyte. In addition, electrochemical stability was measured over 4000 cycles at a scan rate of 100 mV/s in the same electrolyte.

3. Results and Discussion

The SACs were regenerated sequentially by thermal and chemical activation processes, and then washed using three acid solutions. The thermal treatment process converted the adsorbed metal ions into ashes in the pores, which, in turn, decreased the surface areas of the SACs. A washing process is required to remove ashes before the utilisation of regenerated SACs. The acid solutions adopted for the washing processes were selected based on their acidities. As illustrated in Fig. S1, the acidity of the solutions (strong, mild, and weak) was classified based on pKa values [1719]. The acidity of the acids used increased in the following order: HCl > H3PO4 > H2O2, so that the HCl, H3PO4, and H2O2 were strong, mild, and weak acids, respectively, were based on the pKa values.
Fig. 2 illustrates the relationship between ash contents and specific surface area. The specific surface areas of H-SACs were slightly higher than those of the other SACs, but their surface areas were still too low for them to be reused. The surface areas of H-SACs were not fully recovered following thermal treatment alone. However, C-SACs, which were chemically activated and subsequently washed with acid solutions, exhibited higher specific surface areas than H-SACs and SACs. The reduction in ash content following acid washing increases SAC specific surface area, implying that surface area increased following chemical activation, and then the ashes generated from both the thermal and chemical activation processes were removed efficiently by acid treatment [3]. SAC surface area was as follows: C-SAC-HCl > C-SAC-H3PO4 > C-SAC-H2O2, indicating that the surface area increased with an increase in the acidity of the washing solution. The pore size distributions of samples were also shown in the Fig. S2. The pores of SAC and H-SAC were distributed between 3–4 nm. However, those pores were disappeared in the chemically regenerated SACs (C-SAC-HCl, H3PO4, and H2O2). This suggested that the pores shifted to lower smaller micropores (<2 nm), increasing the specific surface areas.
The electrochemical properties of the ACs prepared and commercial carbon (Vulcan XC-72) were investigated by CV. The CV was conducted in 0.5M H2SO4 solution as an electrolyte at different scan rates (10–100 mV/s). Fig. 3 shows the CV curves and the calculated capacitance of SAC, H-SAC, C-SAC-HCl, C-SAC-H3PO4, C-SAC-H2O2, and Vulcan XC-72. The specific capacitance of all the samples were calculated from CV curves using the following equation (1):
(1)
Cs=IdV/(m×ΔV×S)
where Cs is the specific capacitance, ∫IdV is the integrated area of the CV curve, m is the mass of the ACs generated on the electrode, ΔV is the potential window, and S is the potential scan rate [20,21].
As illustrated in Fig. 3a–c, the CV curves of samples exhibit a typical rectangular shape at various scan rates, and the current density increased with an increase in scan rate. In addition, the ACs that were prepared exhibited higher CV areas than commercial carbon (Vulcan XC-72) due to the higher surface areas of the ACs. In particular, surface area influences AC capacitance greatly, because the activated sites for electron adsorption are also increased [22]. Therefore, most ACs subjected to chemical activation and acid washing processes had enhanced the surface areas, in addition to increased capacitance. Furthermore, the ACs treated with acids exhibited the visible redox peaks centred at approximately 0.42 V (oxidation) and 0.3 V (reduction).
Fig. 2d illustrates the capacitance calculated at different scan rates. However, in the present study, the C-SAC-HCl surface area was the highest, although its capacitance was not the highest. The capacitance of C-SAC-H3PO4 was higher than those of the other SACs. The relationship between the SSA and capacitance is presented in Fig. S3. The SAC and H-SAC exhibited the relatively low surface areas, which led to lower capacitance. In addition, both C-SAC-H3PO4 and C-SAC-H2O2 had higher surface areas, and exhibited higher capacitance. Conversely, the capacitance of C-SAC-HCl was lower than those of C-SAC-H3PO4 and C-SAC-H2O2, even though C-SAC-HCl had the highest surface area (1637 m2/g). As aforementioned, treatment of C-SACs with various acids increased surface area; however, there was no relationship between surface area and capacitance. For example, although the surface area of C-SAC treated with the mild acid, H3PO4, was not the highest, it had the highest capacitance.
The mismatched and unexpected results could be due to surface functional groups. Functional groups react with electrons and influence capacitance, and are termed pseudo-capacitors. To validate the results, the measured CV areas were classified into two groups based on the storage types: electrical double layer capacitor (EDLC) and pseudo-capacitors, as shown in Fig. S4. As mentioned above, the EDLC and pseudo-capacitor were highly correlated with the surface areas and surface functional groups, respectively [23]. The red area inside CV area indicates EDLC, while the pink area represents pseudo-capacitor. In particular, redox peaks were detected between 0.2 and 0.6 V in the pseudo-capacitance areas. Redox peaks are caused by the oxidation of functional groups that are generated following acid treatments [24]. Conversely, sharp redox peaks were not observed in the H-SAC due to the elimination of surface functional groups following thermal treatment. The samples were analyzed by the X-ray photoelectron spectroscopy (XPS) to confirm the oxygen functional groups in Fig. S6 and Table S1. The number of oxygen functional groups was varied after thermal and chemical treatments of SACs. The Fig. S6a–e shows the XPS results of SAC, H-SAC, C-SAC-HCl, C-SAC-H3PO4, and C-SAC-H2O2. In addition, Fig. S6f shows the surface concentration of oxygen functional groups [3]. The SAC exhibited the higher oxygen concentrations due to the usage of water treatment process. In contrast, the concentration of thermal treatment of SAC (H-SAC) dramatically was dropped, causing by the removal of oxygen groups. The surface concentration increased again after the additional chemical treatment. Table S1 also shows the sum of oxygen functional groups. It indicated that the oxygen functional groups were increased after the chemical activation, and also affected the redox peaks as mentioned above (Fig. S4).
When compared with the other divided areas, the portion of ELDC out of the total capacitance was higher than that of the pseudo-capacitor, which indicated that surface area was the key factor influencing the total capacitance of samples. The amounts of functional groups could also be compared using elementary analysis (Fig. 4). Both oxygen and hydrogen concentrations decreased after thermal and chemical activation, as shown in Fig. 4b. In particular, the oxygen concentrations in C-SACs decreased lower than 10%, which also indicated lower amounts of oxygen functional groups than in other SACs. The results indicate that EDLC area greatly influenced total capacitance.
Strong acids, in the present case, HCl, efficiently removed ashes from the AC structures [25,26]. The carbon concentrations shown in Fig. 4a were also consistent with the amount of ash removed. The concentrations increased considerably following treatment with HCl, when compared with the other acids. Although the strong acid could remove the ashes efficiently, it could impair the AC structure [27]. Some previous studies have already explored AC stability following acid treatment, and ACs treated with HCl exhibited poorer thermal stability than ACs treated with other acids such as HNO3 and HF [28].
Strong acids erode carbon skeletal structures, and, in turn, decrease their stability. Less stable C-SAC structures could negatively affect their capacitance. Furthermore, washing ACs with H3PO4 modifies their surfaces by increasing oxygen concentrations, which increases capacitance [29]. The presence of oxygenated groups could generate capacitance from quick Faradaic charge transfer reactions (pseudo-capacitance) and electrostatic charging [30]. The contribution of pseudo-capacitance was the highest for C-SAC-H3PO4s at any voltage window, which reflected the higher oxygen concentrations in C-SAC-H3PO4 when compared with the other samples treated with other acids, as shown in Fig. 4b. C-SAC-H3PO4 has significantly higher CO-evolving group contents, which are traditionally associated with quinone/ hydroquinone-like redox activity [31,32].
The electrochemical stability of samples was measured using continuous CV cycling tests as shown in Fig. S5. Fig. 5 shows the specific capacitance based on the CV curves at the 1st, 1000th, 2000th, 3000th, and 4000th cycles. The capacitance at the 1000th cycle was slightly higher when compared with the initial capacitance due to their activation, and then it remained constant. The capacitance did not change after the 4000th cycle, and even the capacitance increased in C-SAC-H3PO4 and C-SAC-H2O2, which indicated that the ACs regenerated using the thermal and chemical activation methods and subsequently washed with mild acids, exhibited higher cyclic stability, and they could be used as capacitors. The results in Fig. S7 also indicate that the regenerated ACs could be used as capacitors. The capacitance observed in the study was approximately 60 F/g at a scan rate of 100 mV/s, which was similar or even higher than the capacitance reported in the previous studies [3337].

4. Conclusions

SACs, which are often landfilled, were regenerated by thermal and chemical activation in sequence, and then applied in capacitors. In the present study, both activation and washing processes were performed. The regeneration processes, converted adsorbates into ashes, which remained in pores and blocked the pores. Pore blockage decreased specific surface area, and limited their applications. Consequently, the generated ashes were removed by washing with acids, namely HCl, H3PO4, and H2O2. The strong acid (HCl) removed the ashes efficiently, exhibited by highest specific surface area (C-SAC-HCl). However, C-SAC-H3PO4 and C-SAC-H2O2, which were treated with mild and weak acids, respectively, exhibited higher capacitance than C-SAC-HCl. Nevertheless, C-SAC-HCl, which exhibited the highest surface area, did not exhibit the highest capacitance, due to its less stable structure. The strong acid facilitated the removal of ashes from the pores, but it may have affected surface structures. In addition, H3PO4 oxidised AC surfaces and generated oxygen functional groups, leading to the higher pseudo-capacitance. Both ash removal and functional group generation in the regenerated ACs highly influenced their electrochemical performance. Regenerated AC stability was also tested using continuous CV cycling tests. The CV cycles were performed over 4000 cycles; however, C-SAC capacitance was not altered, leading to the high stability observed.

Acknowledgment

This work was supported by the Technology Innovation Program (20013038, Development of non-ignition pitch based porous material technology for high adsorption of evaporative emissions) funded By the Ministry of Trade, Industry & Energy (MI, Korea).

Supplementary Information

Supporting Information is available at https://doi.org/10.33961/jecst.2020.01683

Fig. 1
SAC regeneration using thermal and chemical activation.
jecst-2020-01683f1.jpg
Fig. 2
Relationship between the residual ash contents and specific surface area
jecst-2020-01683f2.jpg
Fig. 3
Cyclic voltammetry of SAC, H-SAC, C-SAC-HCl, C-SAC-H3PO4, and C-SAC-H2O2 at 50 (a), 100 (b), and 200 (c) mV/s scan rates, and their calculated capacitance comparison (d).
jecst-2020-01683f3.jpg
Fig. 4
Elementary analysis of C (a), and O, H, and S (b) in SAC, H-SAC, C-SAC-HCl, C-SAC-H3PO4, and C-SAC-H2O2.
jecst-2020-01683f4.jpg
Fig. 5
Capacitance measurements for SAC, H-SAC, C-SAC-HCl, C-SAC-H3PO4, and C-SAC-H2O2 at each 1000th cycle at a scan rate of 100 mV/s.
jecst-2020-01683f5.jpg

References

[1] MN. Nasruddin, MR. Fahmi, CZA. Abidin and TS. Yen, J Phys Conf Ser, 2018, 1116(3), 032022.
crossref
[2] P-J. Lu, H-C. Lin, W-T. Yu and J-M. Chern, J Taiwan Inst Chem Eng, 2011, 42(2), 305–311.
crossref
[3] JE. Park, GB. Lee, BU. Hong and SY. Hwang, Appl Sci, 2019, 9(23), 5132.
crossref
[4] E. Sabio, E. González, J. González, C. González-García, A. Ramiro and J. Gañan, Carbon, 2004, 42(11), 2285–2293.
crossref
[5] D. Bhagawan, S. Poodari, G. Ravi kumar, S. Golla, C. Anand, KS. Banda, V. Himabindu and S. Vidyavathi, J Mater Cycles Waste Manag, 2015, 17(1), 185–193.
crossref pdf
[6] SW. Nahm, WG. Shim, Y-K. Park and SC. Kim, Chem Eng J, 2012, 210, 500–509.
crossref
[7] AL. Cazetta, OP. Junior, AMM. Vargas, AP. da Silva, X. Zou, T. Asefa and VC. Almeida, J Anal Appl Pyrolysis, 2013, 101, 53–60.
crossref
[8] Y. Guo and E. Du, Energy Procedia, 2012, 17, 444–449.
crossref
[9] E. Çalışkan, JM. Bermúdez, JB. Parra, JA. Menéndez, M. Mahramanlıoğlu and CO. Ania, J Environ Manage, 2012, 102, 134–140.
crossref
[10] R. Berenguer, JP. Marco-Lozar, C. Quijada, D. Cazorla-Amorós and E. Morallón, Energy & Fuels, 2010, 24(6), 3366–3372.
crossref
[11] J-Y. So and H-R. Cho, Nucl Eng Technol, 2017, 49(4), 873–880.
crossref
[12] S-G. Kim, H-J. Son, J-M. Jung, D-C. Ryu and P-J. Yoo, J Environ Sci Int, 2015, 24(9), 1163–1170.
crossref pdf
[13] X. Han, E. Wishart and Y. Zheng, Can J Chem Eng, 2014, 92(5), 884–891.
crossref
[14] A. Bagreev, H. Rahman and TJ. Bandosz, Carbon, 2001, 39(9), 1319–1326.
crossref
[15] GB. Lee, JE. Park, SY. Hwang, JH. Kim, S. Kim, H. Kim and BU. Hong, Carbon Lett, 2019, 29(3), 263–272.
crossref pdf
[16] C-H. Lee, H-N. Park, Y-K. Lee, YS. Chung, S. Lee and H-I. Joh, Electrochem Commun, 2019, 106, 106516.
crossref
[17] KP. Gable, Adv Organomet Chem, 1997, 41, 127–161.
crossref
[18] PW. Atkins, Physical Chemistry. Oxford University Press, p.1024. data section. 1997.

[19] VK. Chaudhri, BE. John, S. Mishra, J. Pacheco, B. Porter and A. Spaulding, In: K-CAP’07: Proceedings of the Fourth International Conference on Knowledge Capture; 2007; pp 159–166.

[20] H-I. Joh, HK. Song, C-H. Lee, J-M. Yun, SM. Jo, S. Lee, S-I. Na, A-T. Chien and S. Kumar, Carbon, 2014, 70, 308–312.
crossref
[21] L. Qie, W. Chen, H. Xu, X. Xiong, Y. Jiang, F. Zou, X. Hu, Y. Xin, Z. Zhang and Y. Huang, Energy Environ Sci, 2013, 6(8), 2497–2504.
crossref
[22] TE. Kibona, Appl Sci, 2019, 1(9), 1–11.

[23] D. Kim, K. Lee, M. Kim, Y. Kim and H. Lee, Electrochim Acta, 2019, 300, 461–469.
crossref
[24] J-J. Yang, Y-J. Choi, H-J. Kim, Y-J. Yuk and S-G. Park, J Korean Electrochem Soc, 2013, 16(2), 65–69.
crossref pdf
[25] J. Shah, MR. Jan, F. Mabood and M. Shahid, J Chinese Chem Soc, 2006, 53(5), 1085–1089.
crossref
[26] S. Ouyang, D. Xiong, Y. Xie, L. Ma, Z. Hao, B. Sun, J. Yang, W. Chen and X. Li, Energy Sources, Part A Recover Util Environ Eff, 2019, 1–17.

[27] S-H. Pak, M-J. Jeon and Y-W. Jeon, Int Biodeterior Biodegradation, 2016, 113, 195–200.
crossref
[28] S. Wang and Z. Zhu, Dye Pigment, 2007, 75(2), 306–314.
crossref
[29] V. Ruiz, C. Blanco, E. Raymundo-Piñero, V. Khomenko, F. Béguin and R. Santamaría, Electrochim Acta, 2007, 52(4969), 90.

[30] BE. Conway, Electrochemical Supercapacitors: Scientific Fundamentals and Technological Applications, 1999.

[31] M. Uchimiya and AT. Stone, Geochim Cosmochim Acta, 2006, 70(6), 1388–1401.
crossref
[32] M. Quan, D. Sanchez, MF. Wasylkiw and DK. Smith, J Am Chem Soc, 2007, 129(42), 12847–12856.
crossref
[33] K. Chaitra, RT. Vinny, P. Sivaraman, N. Reddy, C. Hu, K. Venkatesh, CS. Vivek, N. Nagaraju and N. Kathyayini, J Energy Chem, 2017, 26(1), 56–62.
crossref
[34] V. Subramanian, C. Luo, AM. Stephan, KS. Nahm, S. Thomas and B. Wei, J Phys Chem C, 2007, 111(20), 7527–7531.
crossref
[35] C. Kim, J-W. Lee, J-H. Kim and K-S. Yang, Korean J Chem Eng, 2006, 23(4), 592–594.
crossref pdf
[36] C-S. Yang, YS. Jang and HK. Jeong, Curr Appl Phys, 2014, 14(12), 1616–1620.
crossref
[37] S. Kumagai, M. Sato and D. Tashima, Electrochim Acta, 2013, 114, 617–626.
crossref
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 1 Crossref
  • 1 Scopus
  • 9,167 View
  • 106 Download
Related articles in J. Electrochem. Sci. Technol


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
E-mail: journal@kecs.or.kr    Tel: +82-2-568-9392    Fax: +82-2-568-5931                   

Copyright © 2024 by The Korean Electrochemical Society.

Developed in M2PI

Close layer
prev next